ingrPktsΒΆ
| Name | Type | Description | 
|---|---|---|
| floodAvg | integer | Ingress flood average packets. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval. | 
| floodCum | integer | Ingress flood cumulative packets. The total sum of the values read. Note that this value continues through each interval without resetting to zero. | 
| floodMax | integer | Ingress flood maximum packets. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval. | 
| floodMin | integer | Ingress flood minimum packets. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval. | 
| floodPer | integer | Ingress flood packets per interval. The total sum of the values read during the collection interval. Note that this value resets to 0 at the beginning of each interval. | 
| floodRate | float | Ingress flood packets rate. This is the rate of the counter during the collection interval. The rate is calculated by dividing the periodic value by the length of the collection interval in seconds. Note that this value resets to 0 at the beginning of each interval. | 
| multicastAvg | integer | Ingress multicast packet average. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval. | 
| multicastCum | integer | Ingress multicast cumulative packets. The total sum of the values read. Note that this value continues through each interval without resetting to zero. | 
| multicastMax | integer | Ingress multicast packets maximum read. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval. | 
| multicastMin | integer | Ingress multicast packets minimum read. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval. | 
| multicastPer | integer | Ingress multicast packets per interval. The total sum of the values read during the collection interval. Note that this value resets to 0 at the beginning of each interval. | 
| multicastRate | float | Ingress multicast packet rate. This is the rate of the counter during the collection interval. The rate is calculated by dividing the periodic value by the length of the collection interval in seconds. Note that this value resets to 0 at the beginning of each interval. | 
| unicastAvg | integer | Ingress unicast average packets. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval. | 
| unicastCum | integer | Ingress unicast packets cumulative. The total sum of the values read. Note that this value continues through each interval without resetting to zero. | 
| unicastMax | integer | Ingress unicast packets maximum read. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval. | 
| unicastMin | integer | Ingress unicast packets minimum read. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval. | 
| unicastPer | integer | Ingress unicast packets per interval. The total sum of the values read during the collection interval. Note that this value resets to 0 at the beginning of each interval. | 
| unicastRate | float | Ingress unicast packet rate. This is the rate of the counter during the collection interval. The rate is calculated by dividing the periodic value by the length of the collection interval in seconds. Note that this value resets to 0 at the beginning of each interval. | 
| intervalStart | time | Interval start time. Timestamp of when interval started. | 
| intervalEnd | time | Interval end time. Timestamp of when interval ended. |