egrTotalΒΆ
| Name | Type | Description | 
|---|---|---|
| bytesAvg | integer | Egress bytes average This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval. | 
| bytesCum | integer | Egress bytes cumulative. The total sum of the values read. Note that this value continues through each interval without resetting to zero. | 
| bytesMax | integer | Egress bytes maximum. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval. | 
| bytesMin | integer | Egress bytes minimum. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval. | 
| bytesPer | integer | Egress bytes per interval. The total sum of the values read during the collection interval. Note that this value resets to 0 at the beginning of each interval. | 
| bytesRate | float | Egress byte rate. This is the rate of the counter during the collection interval. The rate is calculated by dividing the periodic value by the length of the collection interval in seconds. Note that this value resets to 0 at the beginning of each interval. | 
| bytesRateAvg | float | Egress byte rate average. This is the average value read by the counter during the collection interval. This value resets to 0 at the beginning of each interval and is in bytes per second. | 
| bytesRateMax | float | Egress byte rate maximum. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval. It is in bytes per second. | 
| bytesRateMin | float | Egress byte rate minimum. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval. It is measured in bytes per second. | 
| pktsAvg | integer | Egress packets average. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval. | 
| pktsCum | integer | Egress packets cumulative. The total sum of the values read. Note that this value continues through each interval without resetting to zero. | 
| pktsMax | integer | Egress packets maximum value read. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval. | 
| pktsMin | integer | Egress packets minimum value read. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval. | 
| pktsPer | integer | Egres packets per interval. The total sum of the values read during the collection interval. Note that this value resets to 0 at the beginning of each interval. | 
| pktsRate | float | Egress packet rate. This is the rate of the counter during the collection interval. The rate is calculated by dividing the periodic value by the length of the collection interval in seconds. Note that this value resets to 0 at the beginning of each interval. | 
| pktsRateAvg | float | Egress packet rate average. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval. It is measured in packets per second. | 
| pktsRateMax | float | Egress packet rate maximum. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval. It is measured in packets per second. | 
| pktsRateMin | float | Egress packet rate minimum. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval. It is measured in packets per second. | 
| intervalStart | time | Interval start time. Timestamp of when interval started. | 
| intervalEnd | time | Interval end time. Timestamp of when interval ended. |