egrTotalΒΆ
Name | Type | Description
|
---|---|---|
bytesAvg | integer | Egress bytes average
This is the average value read by the counter
during the collection interval. Note that this
value resets to 0 at the beginning of each
interval.
|
bytesCum | integer | Egress bytes cumulative.
The total sum of the values read. Note that this
value continues through each interval without
resetting to zero.
|
bytesMax | integer | Egress bytes maximum.
This is the largest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
larger than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 4, the previous value is
overwritten with 4. If the third reading is
smaller than 4, the value remains at 4. Note that
this value resets to 0 at the beginning of each
interval.
|
bytesMin | integer | Egress bytes minimum.
This is the smallest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
smaller than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 2, the previous value is
overwritten with 2. If the third reading is
larger than 2, the value remains at 2. Note that
this value resets to 0 at the beginning of each
interval.
|
bytesPer | integer | Egress bytes per interval.
The total sum of the values read during the
collection interval. Note that this value resets
to 0 at the beginning of each interval.
|
bytesRate | float | Egress byte rate.
This is the rate of the counter during the
collection interval. The rate is calculated by
dividing the periodic value by the length of the
collection interval in seconds. Note that this
value resets to 0 at the beginning of each
interval.
|
bytesRateAvg | float | Egress byte rate average.
This is the average value read by the counter
during the collection interval. This value resets
to 0 at the beginning of each interval and is in
bytes per second.
|
bytesRateMax | float | Egress byte rate maximum.
This is the largest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
larger than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 4, the previous value is
overwritten with 4. If the third reading is
smaller than 4, the value remains at 4. Note that
this value resets to 0 at the beginning of each
interval. It is in bytes per second.
|
bytesRateMin | float | Egress byte rate minimum.
This is the smallest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
smaller than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 2, the previous value is
overwritten with 2. If the third reading is
larger than 2, the value remains at 2. Note that
this value resets to 0 at the beginning of each
interval. It is measured in bytes per second.
|
pktsAvg | integer | Egress packets average.
This is the average value read by the counter
during the collection interval. Note that this
value resets to 0 at the beginning of each
interval.
|
pktsCum | integer | Egress packets cumulative.
The total sum of the values read. Note that this
value continues through each interval without
resetting to zero.
|
pktsMax | integer | Egress packets maximum value read.
This is the largest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
larger than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 4, the previous value is
overwritten with 4. If the third reading is
smaller than 4, the value remains at 4. Note that
this value resets to 0 at the beginning of each
interval.
|
pktsMin | integer | Egress packets minimum value read.
This is the smallest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
smaller than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 2, the previous value is
overwritten with 2. If the third reading is
larger than 2, the value remains at 2. Note that
this value resets to 0 at the beginning of each
interval.
|
pktsPer | integer | Egres packets per interval.
The total sum of the values read during the
collection interval. Note that this value resets
to 0 at the beginning of each interval.
|
pktsRate | float | Egress packet rate.
This is the rate of the counter during the
collection interval. The rate is calculated by
dividing the periodic value by the length of the
collection interval in seconds. Note that this
value resets to 0 at the beginning of each
interval.
|
pktsRateAvg | float | Egress packet rate average.
This is the average value read by the counter
during the collection interval. Note that this
value resets to 0 at the beginning of each
interval. It is measured in packets per second.
|
pktsRateMax | float | Egress packet rate maximum.
This is the largest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
larger than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 4, the previous value is
overwritten with 4. If the third reading is
smaller than 4, the value remains at 4. Note that
this value resets to 0 at the beginning of each
interval. It is measured in packets per second.
|
pktsRateMin | float | Egress packet rate minimum.
This is the smallest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
smaller than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 2, the previous value is
overwritten with 2. If the third reading is
larger than 2, the value remains at 2. Note that
this value resets to 0 at the beginning of each
interval. It is measured in packets per second.
|
intervalStart | time | Interval start time.
Timestamp of when interval started.
|
intervalEnd | time | Interval end time.
Timestamp of when interval ended.
|