ingrBytesΒΆ
Name | Type | Description
|
---|---|---|
floodavg | integer | Ingress flood bytes average.
This is the average value read by the counter
during the collection interval. Note that this
value resets to 0 at the beginning of each
interval.
|
floodCum | integer | Ingress flood bytes cumulative.
The total sum of the values read. Note that this
value continues through each interval without
resetting to zero.
|
floodMax | integer | Ingress flood bytes maximum.
This is the largest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
larger than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 4, the previous value is
overwritten with 4. If the third reading is
smaller than 4, the value remains at 4. Note that
this value resets to 0 at the beginning of each
interval.
|
floodMin | integer | Ingress flood bytes minimum.
This is the smallest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
smaller than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 2, the previous value is
overwritten with 2. If the third reading is
larger than 2, the value remains at 2. Note that
this value resets to 0 at the beginning of each
interval.
|
floodPer | integer | Ingress flood bytes total in period
The total sum of the values read during the
collection interval. Note that this value resets
to 0 at the beginning of each interval.
|
multicastAvg | integer | Ingress multicast bytes average.
This is the average value read by the counter
during the collection interval. Note that this
value resets to 0 at the beginning of each
interval.
|
multicastCum | integer | Ingress multicast bytes cumulative.
The total sum of the values read. Note that this
value continues through each interval without
resetting to zero.
|
multicastMax | integer | Ingress multicast bytes maximum.
This is the largest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
larger than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 4, the previous value is
overwritten with 4. If the third reading is
smaller than 4, the value remains at 4. Note that
this value resets to 0 at the beginning of each
interval.
|
multicastMin | integer | Ingress multicast bytes minimum.
This is the smallest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
smaller than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 2, the previous value is
overwritten with 2. If the third reading is
larger than 2, the value remains at 2. Note that
this value resets to 0 at the beginning of each
interval.
|
multicastPer | integer | Ingress multicast bytes per interval.
The total sum of the values read during the
collection interval. Note that this value resets
to 0 at the beginning of each interval.
|
floodRate | float | Ingress flood byte rate
This is the rate of the counter during the
collection interval. The rate is calculated by
dividing the periodic value by the length of the
collection interval in seconds. Note that this
value resets to 0 at the beginning of each
interval.
|
multicastRate | float | Ingress multicast byte rate.
This is the rate of the counter during the
collection interval. The rate is calculated by
dividing the periodic value by the length of the
collection interval in seconds. Note that this
value resets to 0 at the beginning of each
interval.
|
multicastRateAvg | float | Ingress multicast byte rate average.
This is the average value read by the counter
during the collection interval. Note that this
value resets to 0 at the beginning of each
interval. This value is in bytes per second.
|
multicastRateMax | float | Ingress multicast byte rate maximum.
This is the largest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
larger than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 4, the previous value is
overwritten with 4. If the third reading is
smaller than 4, the value remains at 4. Note that
this value resets to 0 at the beginning of each
interval. This value is in bytes per second.
|
multicastRateMin | float | Ingress multicast byte rate minimum
This is the smallest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
smaller than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 2, the previous value is
overwritten with 2. If the third reading is
larger than 2, the value remains at 2. Note that
this value resets to 0 at the beginning of each
interval. This value is in bytes per second.
|
intervalStart | time | Interval start time.
Timestamp of when interval started.
|
intervalEnd | time | Interval end time.
Timestamp of when interval ended.
|