ingrTotalΒΆ
Name | Type | Description
|
---|---|---|
bytesAvg | integer | Ingress bytes average
This is the average value read by the counter
during the collection interval. Note that this
value resets to 0 at the beginning of each
interval.
|
bytesCum | integer | Ingress bytes cumulative.
The total sum of the values read. Note that this
value continues through each interval without
resetting to zero.
|
bytesMax | integer | Ingress bytes maximum.
This is the largest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
larger than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 4, the previous value is
overwritten with 4. If the third reading is
smaller than 4, the value remains at 4. Note that
this value resets to 0 at the beginning of each
interval.
|
bytesMin | integer | Ingress bytes minimum.
This is the smallest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
smaller than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 2, the previous value is
overwritten with 2. If the third reading is
larger than 2, the value remains at 2. Note that
this value resets to 0 at the beginning of each
interval.
|
bytesPer | integer | Ingress bytes per interval.
The total sum of the values read during the
collection interval. Note that this value resets
to 0 at the beginning of each interval.
|
bytesRate | float | Ingress byte rate.
This is the rate of the counter during the
collection interval. The rate is calculated by
dividing the periodic value by the length of the
collection interval in seconds. Note that this
value resets to 0 at the beginning of each
interval.
|
bytesRateAvg | float | Ingress byte rate average.
This is the average value read by the counter
during the collection interval. This value resets
to 0 at the beginning of each interval and is in
bytes per second.
|
bytesRateMax | float | Ingress byte rate maximum.
This is the largest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
larger than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 4, the previous value is
overwritten with 4. If the third reading is
smaller than 4, the value remains at 4. Note that
this value resets to 0 at the beginning of each
interval. It is in bytes per second.
|
bytesRateMin | float | Ingress byte rate minimum.
This is the smallest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
smaller than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 2, the previous value is
overwritten with 2. If the third reading is
larger than 2, the value remains at 2. Note that
this value resets to 0 at the beginning of each
interval. It is measured in bytes per second.
|
pktsAvg | integer | Ingress packets average.
This is the average value read by the counter
during the collection interval. Note that this
value resets to 0 at the beginning of each
interval.
|
pktsCum | integer | Ingress packets cumulative.
The total sum of the values read. Note that this
value continues through each interval without
resetting to zero.
|
pktsMax | integer | Ingress packets maximum value read.
This is the largest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
larger than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 4, the previous value is
overwritten with 4. If the third reading is
smaller than 4, the value remains at 4. Note that
this value resets to 0 at the beginning of each
interval.
|
pktsMin | integer | Ingress packets minimum value read.
This is the smallest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
smaller than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 2, the previous value is
overwritten with 2. If the third reading is
larger than 2, the value remains at 2. Note that
this value resets to 0 at the beginning of each
interval.
|
pktsPer | integer | Egres packets per interval.
The total sum of the values read during the
collection interval. Note that this value resets
to 0 at the beginning of each interval.
|
pktsRate | float | Ingress packet rate.
This is the rate of the counter during the
collection interval. The rate is calculated by
dividing the periodic value by the length of the
collection interval in seconds. Note that this
value resets to 0 at the beginning of each
interval.
|
pktsRateAvg | float | Ingress packet rate average.
This is the average value read by the counter
during the collection interval. Note that this
value resets to 0 at the beginning of each
interval. It is measured in packets per second.
|
pktsRateMax | float | Ingress packet rate maximum.
This is the largest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
larger than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 4, the previous value is
overwritten with 4. If the third reading is
smaller than 4, the value remains at 4. Note that
this value resets to 0 at the beginning of each
interval. It is measured in packets per second.
|
pktsRateMin | float | Ingress packet rate minimum.
This is the smallest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
smaller than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 2, the previous value is
overwritten with 2. If the third reading is
larger than 2, the value remains at 2. Note that
this value resets to 0 at the beginning of each
interval. It is measured in packets per second.
|
intervalStart | time | Interval start time.
Timestamp of when interval started.
|
intervalEnd | time | Interval end time.
Timestamp of when interval ended.
|